Products PRODUCTS

Product name:Linkam THMSG600

brand:Linkam

Place of Origin:Uk

The THMSG600 is based on the design of Linkam’s highly successful THMS600 stage and has been modified specifically for geological applications. Unrivalled accuracy and temperature control enable the user to characterize fluid inclusions to better than 0.1°C and hold a stability of 0.001°C. The THMSG600 has a temperature range of < -195°C to 600°C. The response time to a 'Hold' or 'Limit' command where the temperature is stable to 0.1°C is only 0.1 seconds at 30°C/min. The sample is placed on 7mm quartz cover slip. A pure silver lid can then be placed on top to create an oven so the sample is heated from all sides, ensuring a perfectly uniform temperature. The LNP96 liquid nitrogen cooling pump is used to enable a wide range of cooling rates from 0.01°C to 150°C/min. The highly efficient LNP96, using proprietary pumps and tubing, controls the pumping rate to ensure that minimal liquid nitrogen is required and a consistent smooth cooling curve is produced regardless of the selected rate. The T96-LinkPad temperature controller with LCD touch screen is used to quickly program a temperature profile by simply tapping the onscreen controls. Heating rates have also been increased up to 150°C/min to enable even faster characterization. To control the system from the PC and capture both data and digital images, upgrade the system by adding intuitive LINK software.

Product introductionTechnical specificationsSolutionProduct exhibitions


The THMSG600 is based on the design of Linkam’s highly successful THMS600 stage and has been modified specifically for geological applications.

Unrivalled accuracy and temperature control enable the user to characterize fluid inclusions to better than 0.1°C and hold a stability of 0.001°C. The THMSG600 has a temperature range of < -195°C to 600°C.

The response time to a 'Hold' or 'Limit' command where the temperature is stable to 0.1°C is only 0.1 seconds at 30°C/min.

The sample is placed on 7mm quartz cover slip. A pure silver lid can then be placed on top to create an oven so the sample is heated from all sides, ensuring a perfectly uniform temperature.

The LNP96 liquid nitrogen cooling pump is used to enable a wide range of cooling rates from 0.01°C to 150°C/min.  The highly efficient LNP96, using proprietary pumps and tubing, controls the pumping rate to ensure that minimal liquid nitrogen is required and a consistent smooth cooling curve is produced regardless of the selected rate.

The T96-LinkPad temperature controller with LCD touch screen is used to quickly program a temperature profile by simply tapping the onscreen controls.  Heating rates have also been increased up to 150°C/min to enable even faster characterization.  To control the system from the PC and capture both data and digital images, upgrade the system by adding intuitive LINK software.



· temperature range < -195°C to 600°C

· Up to 150°C/min heating

· Temperature stability <0.1°C

· 16mm XY sample manipulation

· Sample area 22mm diameter

· Quick-release gas valves for atmospheric control

· Clamps directly to the microscope substage for stability

· 100 Ohm platinum resistor sensor

· Light aperture 1.3mm diameter

· Silver heating block for high thermal conductivity

· Direct injection of the coolant into the silver block

· Single ultra thin lid window 0.17mm

· Objective lens working distance 4.8mm

· Condenser lens minimum working distance 12.5mm

· The stage body can be cooled with a water cooling pump for high temperature work (>300°C)

· Suitable for confocal, Laser Raman and X-ray

· Sample side loading without removing the stage lid

· Stage body size 135mm x 92mm x 21.7mm